BCM Series Biological Clean Bench
Biological clean bench is necessary for cell tissue culture in the fields of medicine, biological engineering and scientific lab.
Characteristics:
Biological clean bench is necessary for cell tissue culture in the fields of medicine, biological engineering and scientific lab.
Main characters:
*Collocation for biological operation:
Equipped with discharge interface on the button, and equipped with high effective filter on air outlet.
*Circulated air flow design, when working area supplies fresh air, some return air will be discharge from top.
* Equipped with spring up/down movable door in the front and back of work bench, flexible and convenient to locate.
* Air insulation design to avoid cross pollution inside and outside.
* Equipped with 2kw spare socket to convenient for operator.
Parameter:
| Parameter/Model | BCM-1000 or 1300 |
| Clean grade | ISO5 (class 100) |
| Number of bacteria | ≤0.5 piece per utensil.hour (Φ90mm utensil) |
| Average wind speed | 0.25~0.45m/s (adjustable) |
| Exhaust volume | 2 m3/min or 3 m3/min |
| Noise | ≤62dB (A) |
| Half peak value of shaking | ≤5μm |
| Illumination | ≥300Lx |
| Power supply | AC, single phase 220V/50Hz |
| Max. power consumption | 0.8kw |
| Weight | 300kg or 340kg |
| Dimension (W1: width of working area) | 1000mm or 1300mm |
| Dimension (D1: depth of working area) | 700mm |
| Dimension (H1: height of working area) | 620mm |
| Dimension (W: width of exterior) | 1160mm or 1460mm |
| Dimension (D: depth of exterior) | 760mm |
| Dimension (H: height of exterior) | 1780mm |
| Specification and number of air supply filter | 915*610*50 or 1220*610*50 |
| Specification and number of air discharge filter | 610*90*50 or 610*150*50 |
| Specification and number of light from firefly/ultraviolet light | 20W /20W |
Related Products
-
Walkable ceiling
ultra-med offers a variety of ceiling systems. All systems are absolutely flush in combination with a low portion of joints. They correspond to the system requirements described by GMP & FDA.
The systems are available as walk-on or non-walk-on versions. The panels are sealed or there are used dry gaskets. For every ceiling system ultra-med offers appropriate standard components like luminaires, filter/fan modules or inspection chambers. The systems are modular so dismantling and reassembly can be carried out at any time
Ultra-med can be supply walk-on ceiling same as partition wall panels for special requirements.
Ceiling for use in the pharmaceutical sector, in design suitable for walking on, with under pressure and overpressure values of max. -100 Pa to +200 Pa. The ceiling is made of multi-edged sheet steel carrier elements, suspended with infinite adjustment from the building structure by threaded rods spaced at intervals of 2400 mm. The use of standardized parts makes it the most economical of ceilings that are capable of being walked on.
Flexible adjustments
The ultra-med ceiling system is suitable for any design or size of clean room installations. The grid dimensions have been standardized and as a result it offers a fast and safe planning. This also offers a flexible design and clean room size. The ceiling is flexible, too. Each individual element can be removed independently of the adjacent areas, the cassettes are mutually interchangeable, and dismantling and reassembly can be carried out at any time.
-
Roll-Up doors
The panel is flexible with no rigid elements, it is self-repairing as it automatically fits back onto the slide rails, and rolls up inside the box which houses the motor.
They are fast moving and flexible doors that provide easy and functional transportation of materials from one area to another within the clean room.
Sliding guides and structures in painted steel, fiberglass.
It is also possible to insert transparent bands, which allow visibility through the roller blind.
Sheet: reinforced polyester (PE-UHMW 1000)
Opening speed: up to 1.5 m/s
Application: ultra-med partition plasterboard or brick wall
Sheet colors: according to customer request.
-
Pass Box
Passive Pass Box
Complete system for the passage of small objects between two different class rooms, fully integrated and flush-fitted to the partition wall. The Pass-Box doors are made using stainless steel natural color with double glass and stainless steel handles and perimeter tight seal gaskets.
Electrical Interlock between 2 doors.
Dynamic Pass Box
The Pass-Box doors are made using stainless steel natural color with double glass and stainless steel handles and perimeter tight seal gaskets.
Electrical interlock between 2 doors, H14 HEPA filter and circulation Fan and UV light.
-
Clean Room
What is Clean Room?
A Clean Room is an environment, typically used in manufacturing or scientific research that has a low level of environmental pollutants such as dust, airborne microbes, aerosol particles and chemical vapors. More accurately, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5µm and larger in diameter, corresponding to an ISO9 cleanroom, while an ISO1 cleanroom allows no particles in that size range and only 12 particles per cubic meter of 0.3µm and smaller.
What we can do?
We kindly needs following information to design your clean room
- Panel style:
- Metal-face polyurethane core board,
- Metal-face Rockwool core board (widely used),
- Metal-face polystyrene core board (without fire proof),
- Metal-Face Honeycomb Core Board,
- Metal-Face Plastered Core Board (widely used for ceiling),
- Metal-face glass-magnesium core board.
- Panel thickness: 50 mm, 70 mm and 100 mm.
- Panel Height & Color: according to customer request.
- Doors and windows manufacturing.
- Layout drawings.