BSC1300II AB3 Clean Biological Safety Cabinet
BSC-1300II A/B3 clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Characteristics:
BSC-1300II A/B3 clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Main characters:
Air insulation design avoids cross pollution inside and outside. Air cross pollution inside.
Movable limit switch reminds operator at any moment
Equipped with special filter on ventilation to keep vented air conforming to national standard.
Equipped with special waterproofing socket and discharge interface to convenient operator
Designed as electric movable door; control way adopts remote control and foot control.
parameter
| Parameter/model | BSC-1200IIA2 | BSC-1200IIB1 | BSC-1200IIB2 |
| Clean grade | ISO5 (class 100)
100 Grade@≥0.5μm (209E) |
||
| Number of bacteria | ≤0.5 per utensil.hour(Φ90m utensil) | ||
| Air tightness | 500 Pa leakage rate≤10% (in 30min) | ||
| Noisiness | ≤62dB | ||
| Vibration half peak value | ≤5μm | ||
| Illumination | ≥500Lx | ||
| Power supply | AC, Φ1220V/50Hz | ||
| Rated power consumption | 0.8kw | ||
| Equiblast Speed | 0.25-0.45m/s (adjustable) | ||
| Equiblast air volume | ≥0.5m/s | ||
| Weight | 280kg | 300kg | 350kg |
| Dimension of working area (W1 x D1 x H1) | 1200x600x650mm | 1200x600x650mm | 1200x600x650mm |
| Overall dimension(W1xD1xH1) | 1400x800x2230mm | 1400x800x2230mm | 1400x800x2230m |
| Specification and number of air supply filter | 1170x520x70 | 1170x520x70 | 1170x520x70 |
| Specification and number of air discharge filter specification and number | 610x305x90 | 968x484x90 | 968x610x70 |
| Light from firefly/ultraviolet light | 40W/30W | 40W/30W | 40W/30W |
| Remark | 30% exhaust air rate | 70% exhaust air rate | 100% exhaust air rate |
Related Products
-
Isolator
Isolator is made according to CGMP and EGMP standard, special designed to make high standard sterile space, the equipment adopts high standard fast transferring technology (RTP) and auto sterilization killing technology, the sealing cabinet achieve air exchange through high effective filter to prevent the animalcule in environment coming into the separator. Used for sterile production and sterile testing.
-
HPL wall
The HPL partition wall is a structure with a thickness of 45 mm, made of 2 x 4 mm thick external HPL panels and internal insulation, which vary according to the project requirements.
Each panel made is completely sealed on all 4 sides, using extruded aluminum profiles, designed to create the structure and complete closure of the internal insulation.
ultra-med supplies different types of insulation: rock wool (RW), polystyrene (EPS), aluminum and paper honeycomb (HC), polyurethane (PUR).
In all cases, the densities of such insulations are extremely high, so as to guarantee superior mechanical stability of the wall itself.
-
Clean Room
A Clean Room is an environment, typically used in manufacturing or scientific research that has a low level of environmental pollutants such as dust, airborne microbes, aerosol particles and chemical vapors. More accurately, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5µm and larger in diameter, corresponding to an ISO9 cleanroom, while an ISO1 cleanroom allows no particles in that size range and only 12 particles per cubic meter of 0.3µm and smaller.
-
Clip-in Ceiling System
ultra-med offers a variety of ceiling systems. All systems are absolutely flush in combination with a low portion of joints. They correspond to the system requirements described by GMP & FDA.
The systems are available as walk-on or non-walk-on versions. The panels are sealed or there are used dry gaskets. For every ceiling system ultra-med offers appropriate standard components like luminaires, filter/fan modules or inspection chambers. The systems are modular so dismantling and reassembly can be carried out at any time
ultra-med Clip-In ceiling system has a beveled edge to form visually closed joints. The 4.2 mm bevel will emphasize the crispness of the tile ceiling design with fine joint lines.
ultra-med Clip-In ceiling system are made of 0.6 mm thick Galvanized steel or Aluminum in powder coated with standard color RAL 9010.
ultra-med Clip-In ceiling system are available in a wide variety of pre-defined rectangular module sizes that are commonly used in ceiling design.
Ceiling Tile Size (mm) Side Height (mm) Thickness (mm) 300 x 300 20/25 0.5-1 300 x 600 20/25 0.6-1 300 x 1200 20/25 0.7-1 400 x 400 20 0.6-1 500 x 500 20 0.6-1 600 x 600 20/25/28 0.6-1.2 600 x 1200 20/25/28 0.7-1.2









Reviews
There are no reviews yet.