BSC1300II AB3 Clean Biological Safety Cabinet
BSC-1300II A/B3 clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Characteristics:
BSC-1300II A/B3 clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Main characters:
Air insulation design avoids cross pollution inside and outside. Air cross pollution inside.
Movable limit switch reminds operator at any moment
Equipped with special filter on ventilation to keep vented air conforming to national standard.
Equipped with special waterproofing socket and discharge interface to convenient operator
Designed as electric movable door; control way adopts remote control and foot control.
parameter
| Parameter/model | BSC-1200IIA2 | BSC-1200IIB1 | BSC-1200IIB2 |
| Clean grade | ISO5 (class 100)
100 Grade@≥0.5μm (209E) |
||
| Number of bacteria | ≤0.5 per utensil.hour(Φ90m utensil) | ||
| Air tightness | 500 Pa leakage rate≤10% (in 30min) | ||
| Noisiness | ≤62dB | ||
| Vibration half peak value | ≤5μm | ||
| Illumination | ≥500Lx | ||
| Power supply | AC, Φ1220V/50Hz | ||
| Rated power consumption | 0.8kw | ||
| Equiblast Speed | 0.25-0.45m/s (adjustable) | ||
| Equiblast air volume | ≥0.5m/s | ||
| Weight | 280kg | 300kg | 350kg |
| Dimension of working area (W1 x D1 x H1) | 1200x600x650mm | 1200x600x650mm | 1200x600x650mm |
| Overall dimension(W1xD1xH1) | 1400x800x2230mm | 1400x800x2230mm | 1400x800x2230m |
| Specification and number of air supply filter | 1170x520x70 | 1170x520x70 | 1170x520x70 |
| Specification and number of air discharge filter specification and number | 610x305x90 | 968x484x90 | 968x610x70 |
| Light from firefly/ultraviolet light | 40W/30W | 40W/30W | 40W/30W |
| Remark | 30% exhaust air rate | 70% exhaust air rate | 100% exhaust air rate |
Related Products
-
Clip-in Ceiling System
ultra-med offers a variety of ceiling systems. All systems are absolutely flush in combination with a low portion of joints. They correspond to the system requirements described by GMP & FDA.
The systems are available as walk-on or non-walk-on versions. The panels are sealed or there are used dry gaskets. For every ceiling system ultra-med offers appropriate standard components like luminaires, filter/fan modules or inspection chambers. The systems are modular so dismantling and reassembly can be carried out at any time
ultra-med Clip-In ceiling system has a beveled edge to form visually closed joints. The 4.2 mm bevel will emphasize the crispness of the tile ceiling design with fine joint lines.
ultra-med Clip-In ceiling system are made of 0.6 mm thick Galvanized steel or Aluminum in powder coated with standard color RAL 9010.
ultra-med Clip-In ceiling system are available in a wide variety of pre-defined rectangular module sizes that are commonly used in ceiling design.
Ceiling Tile Size (mm) Side Height (mm) Thickness (mm) 300 x 300 20/25 0.5-1 300 x 600 20/25 0.6-1 300 x 1200 20/25 0.7-1 400 x 400 20 0.6-1 500 x 500 20 0.6-1 600 x 600 20/25/28 0.6-1.2 600 x 1200 20/25/28 0.7-1.2 -
Pass Box
Pass box is a kind of auxiliary equipment of clean room, used for cargo transfer between clean areas,
clean areas and unclean areas, they can reduce the times to open the door so as to ensure the cleanliness in the clean room.
the pass box is interlock on the both doors,and can not be opened at one time.they can prevent air pollution.
Tip: this model pass box can’t completely to stop dust entrance.
- Air shower pass box:
Air shower pass box is high efficiency filter and fan built-in in normal pass box.
It is suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
- Laminar flow pass box:
It is also suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
But it is mainly applied to the Biopharmaceutical industry,and through the laminar flow filter to form the class100 clean area in laminar flow pass box,thus effectively prevent the pollution into clean room.
-
Roll-Up doors
The panel is flexible with no rigid elements, it is self-repairing as it automatically fits back onto the slide rails, and rolls up inside the box which houses the motor.
They are fast moving and flexible doors that provide easy and functional transportation of materials from one area to another within the clean room.
Sliding guides and structures in painted steel, fiberglass.
It is also possible to insert transparent bands, which allow visibility through the roller blind.
Sheet: reinforced polyester (PE-UHMW 1000)
Opening speed: up to 1.5 m/s
Application: ultra-med partition plasterboard or brick wall
Sheet colors: according to customer request.
-
Fan Filter Unit
FFU series fan filter unit designed and made with international advanced technology, applicable to clean grade as class 100-I clean environment. It can provide the high quality clean air to the clean room with different size and clean grade. Not only improve the clean grade to lower noise and vibration, but also to reduce the cost. It is the essential part in the clean environment.










Reviews
There are no reviews yet.