HPL wall
The HPL partition wall is a structure with a thickness of 45 mm, made of 2 x 4 mm thick external HPL panels and internal insulation, which vary according to the project requirements.
Each panel made is completely sealed on all 4 sides, using extruded aluminum profiles, designed to create the structure and complete closure of the internal insulation.
ultra-med supplies different types of insulation: rock wool (RW), polystyrene (EPS), aluminum and paper honeycomb (HC), polyurethane (PUR).
In all cases, the densities of such insulations are extremely high, so as to guarantee superior mechanical stability of the wall itself.
Insulation Materials:
- POLYSTYRENE [PL]
Sheets of expanded polystyrene (EPS).
Density 35 Kg/cbm, fire reaction class E (EN 13501-1) declared thermal conductivity (λ) = 0.033 W/mK (EN 12667 or 13163)
- ROCKWOOL [RW]
Sheets of fireproof rock wool oriented perpendicular to the plane.
Density 100 Kg/cbm, fire reaction class A1 (EN 13501-1) declared thermal conductivity (λ) = 0.037 W/mK (EN 12667 or 14303)
- ALUMINIUM HONEYCOMB [HC]
Sheets of honeycomb aluminum-combustible, consisting of hexagonal cells with a diameter of 12 mm made of aluminum alloy 3003.
Density 35 Kg/cbm, fire reaction class A0 (EN 13501-1) declared thermal conductivity (λ) = 0.026 W/mK (static air) 0.026 W/mK (static air)
- POLYURETHANE [PU]
Sheets of expanded polyurethane.
Density 35 Kg/cbm, fire reaction class B3 (EN 13501-1 or DIN 4102) declared thermal conductivity (λ) = 0.022 W/mK (EN 12667)
It is a latest generation composite material, used extensively in the construction sector thanks to its high mechanical qualities. It is ideal for environments with a relative humidity of <25% and consists of a central core (2) in IDPE, covered on both sides by an aluminum panel (1) pre-painted 25 micron – Kynar 500 ref. (EN AW-3005 (A) (Al Mn 1mg 0,5) ACC. EN 573) H42.
Related Products
-
Pass Box
Pass box is a kind of auxiliary equipment of clean room, used for cargo transfer between clean areas,
clean areas and unclean areas, they can reduce the times to open the door so as to ensure the cleanliness in the clean room.
the pass box is interlock on the both doors,and can not be opened at one time.they can prevent air pollution.
Tip: this model pass box can’t completely to stop dust entrance.
- Air shower pass box:
Air shower pass box is high efficiency filter and fan built-in in normal pass box.
It is suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
- Laminar flow pass box:
It is also suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
But it is mainly applied to the Biopharmaceutical industry,and through the laminar flow filter to form the class100 clean area in laminar flow pass box,thus effectively prevent the pollution into clean room.
-
Sliding doors
Sliding door consisting of a 45-50 mm extruded aluminum frame and a panel made with the same as the partition walls material, allowing total flush-fitting between the components and the wall itself.
It is simple to assemble as both the electric drive unit and electric panel are housed in a single extruded aluminum cabinet that, when positioned alongside the aluminum perimeter profiles of the door wings and the connection profiles, creates a locking element that blends harmoniously with the clean room environment.
This system can be equipped with a back-up battery which guarantees opening in case of power failure.
Safe and extremely silent thanks to the 100-240 V brushless motor inverter
(50-60Hz) using switch mode technology.
Opening speed 0.8 m/s.
Control unit with microprocessor logic and anti-crushing device complete the features of this clean room sliding door mechanism.
The end customer can choose from the various door opening and control options.
Manual non-motorized version also available. -
Glass Panel Walls
The glass panel wall system by ultra-med adopted is completely flush-mounted and perfectly integrated with the other partition walls that are installed adjacent to the same. A completely concealed fixing and installation system and a minimal perimeter frame complete the product.
They are used for evident aesthetic reasons, boasting in their simplicity an excellent architectural solution but, above all, to make it easier to control and communicate in different environments and, last but not least, to allow visitors to visit the clean rooms directly from the corridors around the areas of production.
The thickness of the glass walls is always 45 – 50 mm, composed of a double layer of 3 – 4 mm laminated safety glass. The width and height of these glass walls, follow very precise rules envisaged by ultra-med, once again to distinguish the design of the product.
It is possible to customize the glass panels inserting screen prints with your company logo.
Full glass panel walls:
Complete system with glass walls and doors perfectly flush with the partition walls. Consistent thickness of 45 – 50 mm.
To exploit the sunlight, to make supervision and communication easier, to allow your customers to view your work from the visitor corridor.
Standard module dimensions FULL GLASS: 1180 x h. 2000 mm. -
Isolator
Isolator is made according to CGMP and EGMP standard, special designed to make high standard sterile space, the equipment adopts high standard fast transferring technology (RTP) and auto sterilization killing technology, the sealing cabinet achieve air exchange through high effective filter to prevent the animalcule in environment coming into the separator. Used for sterile production and sterile testing.