VS Series Vertical Air Flow Clean Bench
This is a kind of new unidirectional air flow clean bench designed and made with international advanced technology, adopting fan system with air volume adjustable and matched with movable door free to locate. Contact switch adjusts voltage to keep wind speed in working area in ideal state all the time.
Characteristics:
This is a kind of new unidirectional air flow clean bench designed and made with international advanced technology, adopting fan system with air volume adjustable and matched with movable door free to locate. Contact switch adjusts voltage to keep wind speed in working area in ideal state all the time.
It is widely used in medicine, pharmacy, biological & chemical experiment, electron, precise apparatus, instrument and so on.
Parameter:
| Parameter/Model | VSF-840 | VS-1300 | VSF-1300CS | TVS-650 |
| Clean grade | ISO5 (class 100) | |||
| Number of bacteria | ≤0.5per utensil.hour (Φ90mm utensil) | |||
| Average wind speed | 0.3-0.6m/s adjustable | |||
| Noisiness | ≤62dB | |||
| Vibration half peak value | ≤5μm | |||
| Illumination | ≥300Lx | |||
| Power supply | AC single phase 220V/50Hz | |||
| Rated power consumption | 0.4KW | 0.8KW | 0.8KW | 0.2KW |
| Weight | 180kgs | 280kgs | 250kgs | 30kgs |
| Dimension of working area
(W1xD1xH1) |
800x680x570mm | 1120x650x720mm | 1280x650x600mm | 615x495x500
mm |
| Overall dimension
(W1xD1xH1) |
840x700x1610mm | 1300x825x1760
mm |
1300x800x1700
mm |
650x535x835
mm |
| Specification and number of high effective filter | 760x610x50 | 610x610x50 | 1220x610x50 | 610x450x50 |
| Specification and number of light from firefly/ultraviolet light | 20W | 30W | 20W | 20W |
| Suitable number | Single | Double | Single | Single |
Related Products
-
Clean Room
A Clean Room is an environment, typically used in manufacturing or scientific research that has a low level of environmental pollutants such as dust, airborne microbes, aerosol particles and chemical vapors. More accurately, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5µm and larger in diameter, corresponding to an ISO9 cleanroom, while an ISO1 cleanroom allows no particles in that size range and only 12 particles per cubic meter of 0.3µm and smaller.
-
Roll-Up doors
The panel is flexible with no rigid elements, it is self-repairing as it automatically fits back onto the slide rails, and rolls up inside the box which houses the motor.
They are fast moving and flexible doors that provide easy and functional transportation of materials from one area to another within the clean room.
Sliding guides and structures in painted steel, fiberglass.
It is also possible to insert transparent bands, which allow visibility through the roller blind.
Sheet: reinforced polyester (PE-UHMW 1000)
Opening speed: up to 1.5 m/s
Application: ultra-med partition plasterboard or brick wall
Sheet colors: according to customer request.
-
Clip-in Ceiling System
ultra-med offers a variety of ceiling systems. All systems are absolutely flush in combination with a low portion of joints. They correspond to the system requirements described by GMP & FDA.
The systems are available as walk-on or non-walk-on versions. The panels are sealed or there are used dry gaskets. For every ceiling system ultra-med offers appropriate standard components like luminaires, filter/fan modules or inspection chambers. The systems are modular so dismantling and reassembly can be carried out at any time
ultra-med Clip-In ceiling system has a beveled edge to form visually closed joints. The 4.2 mm bevel will emphasize the crispness of the tile ceiling design with fine joint lines.
ultra-med Clip-In ceiling system are made of 0.6 mm thick Galvanized steel or Aluminum in powder coated with standard color RAL 9010.
ultra-med Clip-In ceiling system are available in a wide variety of pre-defined rectangular module sizes that are commonly used in ceiling design.
Ceiling Tile Size (mm) Side Height (mm) Thickness (mm) 300 x 300 20/25 0.5-1 300 x 600 20/25 0.6-1 300 x 1200 20/25 0.7-1 400 x 400 20 0.6-1 500 x 500 20 0.6-1 600 x 600 20/25/28 0.6-1.2 600 x 1200 20/25/28 0.7-1.2 -
Pass Box
Pass box is a kind of auxiliary equipment of clean room, used for cargo transfer between clean areas,
clean areas and unclean areas, they can reduce the times to open the door so as to ensure the cleanliness in the clean room.
the pass box is interlock on the both doors,and can not be opened at one time.they can prevent air pollution.
Tip: this model pass box can’t completely to stop dust entrance.
- Air shower pass box:
Air shower pass box is high efficiency filter and fan built-in in normal pass box.
It is suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
- Laminar flow pass box:
It is also suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
But it is mainly applied to the Biopharmaceutical industry,and through the laminar flow filter to form the class100 clean area in laminar flow pass box,thus effectively prevent the pollution into clean room.