BCM Series Biological Clean Bench
Biological clean bench is necessary for cell tissue culture in the fields of medicine, biological engineering and scientific lab.
Characteristics:
Biological clean bench is necessary for cell tissue culture in the fields of medicine, biological engineering and scientific lab.
Main characters:
*Collocation for biological operation:
Equipped with discharge interface on the button, and equipped with high effective filter on air outlet.
*Circulated air flow design, when working area supplies fresh air, some return air will be discharge from top.
* Equipped with spring up/down movable door in the front and back of work bench, flexible and convenient to locate.
* Air insulation design to avoid cross pollution inside and outside.
* Equipped with 2kw spare socket to convenient for operator.
Parameter:
| Parameter/Model | BCM-1000 or 1300 |
| Clean grade | ISO5 (class 100) |
| Number of bacteria | ≤0.5 piece per utensil.hour (Φ90mm utensil) |
| Average wind speed | 0.25~0.45m/s (adjustable) |
| Exhaust volume | 2 m3/min or 3 m3/min |
| Noise | ≤62dB (A) |
| Half peak value of shaking | ≤5μm |
| Illumination | ≥300Lx |
| Power supply | AC, single phase 220V/50Hz |
| Max. power consumption | 0.8kw |
| Weight | 300kg or 340kg |
| Dimension (W1: width of working area) | 1000mm or 1300mm |
| Dimension (D1: depth of working area) | 700mm |
| Dimension (H1: height of working area) | 620mm |
| Dimension (W: width of exterior) | 1160mm or 1460mm |
| Dimension (D: depth of exterior) | 760mm |
| Dimension (H: height of exterior) | 1780mm |
| Specification and number of air supply filter | 915*610*50 or 1220*610*50 |
| Specification and number of air discharge filter | 610*90*50 or 610*150*50 |
| Specification and number of light from firefly/ultraviolet light | 20W /20W |
Related Products
-
Clean Room
A Clean Room is an environment, typically used in manufacturing or scientific research that has a low level of environmental pollutants such as dust, airborne microbes, aerosol particles and chemical vapors. More accurately, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5µm and larger in diameter, corresponding to an ISO9 cleanroom, while an ISO1 cleanroom allows no particles in that size range and only 12 particles per cubic meter of 0.3µm and smaller.
-
Sliding doors
Sliding door consisting of a 45-50 mm extruded aluminum frame and a panel made with the same as the partition walls material, allowing total flush-fitting between the components and the wall itself.
It is simple to assemble as both the electric drive unit and electric panel are housed in a single extruded aluminum cabinet that, when positioned alongside the aluminum perimeter profiles of the door wings and the connection profiles, creates a locking element that blends harmoniously with the clean room environment.
This system can be equipped with a back-up battery which guarantees opening in case of power failure.
Safe and extremely silent thanks to the 100-240 V brushless motor inverter
(50-60Hz) using switch mode technology.
Opening speed 0.8 m/s.
Control unit with microprocessor logic and anti-crushing device complete the features of this clean room sliding door mechanism.
The end customer can choose from the various door opening and control options.
Manual non-motorized version also available. -
Clean Room
What is Clean Room?
A Clean Room is an environment, typically used in manufacturing or scientific research that has a low level of environmental pollutants such as dust, airborne microbes, aerosol particles and chemical vapors. More accurately, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5µm and larger in diameter, corresponding to an ISO9 cleanroom, while an ISO1 cleanroom allows no particles in that size range and only 12 particles per cubic meter of 0.3µm and smaller.
What we can do?
We kindly needs following information to design your clean room
- Panel style:
- Metal-face polyurethane core board,
- Metal-face Rockwool core board (widely used),
- Metal-face polystyrene core board (without fire proof),
- Metal-Face Honeycomb Core Board,
- Metal-Face Plastered Core Board (widely used for ceiling),
- Metal-face glass-magnesium core board.
- Panel thickness: 50 mm, 70 mm and 100 mm.
- Panel Height & Color: according to customer request.
- Doors and windows manufacturing.
- Layout drawings.
-
Air Shower
This is a kind of local purifying equipment, fixed on the partition between clean room and unclean room. It is used for shower and removing dust when personnel or objects entering into clean area. Effectively reduce dust source from entering into clean area after used, and keep clean area in normal working state. Shower way: single-side shower, double-side shower, three-side shower, top shower







Reviews