BSC1300II AB3 Clean Biological Safety Cabinet
BSC-1300II A/B3 clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Characteristics:
BSC-1300II A/B3 clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Main characters:
Air insulation design avoids cross pollution inside and outside. Air cross pollution inside.
Movable limit switch reminds operator at any moment
Equipped with special filter on ventilation to keep vented air conforming to national standard.
Equipped with special waterproofing socket and discharge interface to convenient operator
Designed as electric movable door; control way adopts remote control and foot control.
parameter
| Parameter/model | BSC-1200IIA2 | BSC-1200IIB1 | BSC-1200IIB2 |
| Clean grade | ISO5 (class 100)
100 Grade@≥0.5μm (209E) |
||
| Number of bacteria | ≤0.5 per utensil.hour(Φ90m utensil) | ||
| Air tightness | 500 Pa leakage rate≤10% (in 30min) | ||
| Noisiness | ≤62dB | ||
| Vibration half peak value | ≤5μm | ||
| Illumination | ≥500Lx | ||
| Power supply | AC, Φ1220V/50Hz | ||
| Rated power consumption | 0.8kw | ||
| Equiblast Speed | 0.25-0.45m/s (adjustable) | ||
| Equiblast air volume | ≥0.5m/s | ||
| Weight | 280kg | 300kg | 350kg |
| Dimension of working area (W1 x D1 x H1) | 1200x600x650mm | 1200x600x650mm | 1200x600x650mm |
| Overall dimension(W1xD1xH1) | 1400x800x2230mm | 1400x800x2230mm | 1400x800x2230m |
| Specification and number of air supply filter | 1170x520x70 | 1170x520x70 | 1170x520x70 |
| Specification and number of air discharge filter specification and number | 610x305x90 | 968x484x90 | 968x610x70 |
| Light from firefly/ultraviolet light | 40W/30W | 40W/30W | 40W/30W |
| Remark | 30% exhaust air rate | 70% exhaust air rate | 100% exhaust air rate |
Related Products
-
Clip-in Ceiling System
ultra-med offers a variety of ceiling systems. All systems are absolutely flush in combination with a low portion of joints. They correspond to the system requirements described by GMP & FDA.
The systems are available as walk-on or non-walk-on versions. The panels are sealed or there are used dry gaskets. For every ceiling system ultra-med offers appropriate standard components like luminaires, filter/fan modules or inspection chambers. The systems are modular so dismantling and reassembly can be carried out at any time
ultra-med Clip-In ceiling system has a beveled edge to form visually closed joints. The 4.2 mm bevel will emphasize the crispness of the tile ceiling design with fine joint lines.
ultra-med Clip-In ceiling system are made of 0.6 mm thick Galvanized steel or Aluminum in powder coated with standard color RAL 9010.
ultra-med Clip-In ceiling system are available in a wide variety of pre-defined rectangular module sizes that are commonly used in ceiling design.
Ceiling Tile Size (mm) Side Height (mm) Thickness (mm) 300 x 300 20/25 0.5-1 300 x 600 20/25 0.6-1 300 x 1200 20/25 0.7-1 400 x 400 20 0.6-1 500 x 500 20 0.6-1 600 x 600 20/25/28 0.6-1.2 600 x 1200 20/25/28 0.7-1.2 -
Roll-Up doors
The panel is flexible with no rigid elements, it is self-repairing as it automatically fits back onto the slide rails, and rolls up inside the box which houses the motor.
They are fast moving and flexible doors that provide easy and functional transportation of materials from one area to another within the clean room.
Sliding guides and structures in painted steel, fiberglass.
It is also possible to insert transparent bands, which allow visibility through the roller blind.
Sheet: reinforced polyester (PE-UHMW 1000)
Opening speed: up to 1.5 m/s
Application: ultra-med partition plasterboard or brick wall
Sheet colors: according to customer request.
-
Air Shower
This is a kind of local purifying equipment, fixed on the partition between clean room and unclean room. It is used for shower and removing dust when personnel or objects entering into clean area. Effectively reduce dust source from entering into clean area after used, and keep clean area in normal working state. Shower way: single-side shower, double-side shower, three-side shower, top shower
-
Isolator
Isolator is made according to CGMP and EGMP standard, special designed to make high standard sterile space, the equipment adopts high standard fast transferring technology (RTP) and auto sterilization killing technology, the sealing cabinet achieve air exchange through high effective filter to prevent the animalcule in environment coming into the separator. Used for sterile production and sterile testing.









Reviews
There are no reviews yet.