Galvanized Steel Wall
The Galvanized Steel (GS) partition wall is a structure with a thickness of
50 mm, made of 2 x 0.6 mm thick external Galvanized Steel panels, 2 x 5 mm flameproof board and internal insulation, which vary according to the project requirements.
Each panel made is completely sealed on all 4 sides, using special profiles, designed to create the structure and complete closure of the internal insulation.
Ultra-med supplies different types of insulation: rock wool (RW), polystyrene (EPS), aluminum and paper honeycomb (HC), polyurethane (PUR).
In all cases, the densities of such insulations are extremely high, so as to guarantee superior mechanical stability of the wall itself.
Insulation Materials:
- POLYSTYRENE [PL]
Sheets of expanded polystyrene (EPS).
Density 35 Kg/cbm, fire reaction class E (EN 13501-1) declared thermal conductivity (λ) = 0.033 W/mK (EN 12667 or 13163)
- ROCKWOOL [RW]
Sheets of fireproof rock wool oriented perpendicular to the plane.
Density 100 Kg/cbm, fire reaction class A1 (EN 13501-1) declared thermal conductivity (λ) = 0.037 W/mK (EN 12667 or 14303)
- ALUMINIUM HONEYCOMB [HC]
Sheets of honeycomb aluminum-combustible, consisting of hexagonal cells with a diameter of 12 mm made of aluminum alloy 3003.
Density 35 Kg/cbm, fire reaction class A0 (EN 13501-1) declared thermal conductivity (λ) = 0.026 W/mK (static air) 0.026 W/mK (static air)
- POLYURETHANE [PU]
Sheets of expanded polyurethane.
Density 35 Kg/cbm, fire reaction class B3 (EN 13501-1 or DIN 4102) declared thermal conductivity (λ) = 0.022 W/mK (EN 12667)
It is a latest generation composite material, used extensively in the construction sector thanks to its high mechanical qualities. It is ideal for environments with a relative humidity of <25% and consists of a central core (2) in IDPE, covered on both sides by an aluminum panel (1) pre-painted 25 micron – Kynar 500 ref. (EN AW-3005 (A) (Al Mn 1mg 0,5) ACC. EN 573) H42.
Related Products
-
Pass Box
Pass box is a kind of auxiliary equipment of clean room, used for cargo transfer between clean areas,
clean areas and unclean areas, they can reduce the times to open the door so as to ensure the cleanliness in the clean room.
the pass box is interlock on the both doors,and can not be opened at one time.they can prevent air pollution.
Tip: this model pass box can’t completely to stop dust entrance.
- Air shower pass box:
Air shower pass box is high efficiency filter and fan built-in in normal pass box.
It is suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
- Laminar flow pass box:
It is also suitable for cargo transfer from clean areas to unclean areas or from low clean areas to high clean areas.
But it is mainly applied to the Biopharmaceutical industry,and through the laminar flow filter to form the class100 clean area in laminar flow pass box,thus effectively prevent the pollution into clean room.
-
HPL wall
The HPL partition wall is a structure with a thickness of 45 mm, made of 2 x 4 mm thick external HPL panels and internal insulation, which vary according to the project requirements.
Each panel made is completely sealed on all 4 sides, using extruded aluminum profiles, designed to create the structure and complete closure of the internal insulation.
ultra-med supplies different types of insulation: rock wool (RW), polystyrene (EPS), aluminum and paper honeycomb (HC), polyurethane (PUR).
In all cases, the densities of such insulations are extremely high, so as to guarantee superior mechanical stability of the wall itself.
-
Clean Room
A Clean Room is an environment, typically used in manufacturing or scientific research that has a low level of environmental pollutants such as dust, airborne microbes, aerosol particles and chemical vapors. More accurately, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5µm and larger in diameter, corresponding to an ISO9 cleanroom, while an ISO1 cleanroom allows no particles in that size range and only 12 particles per cubic meter of 0.3µm and smaller.
-
BCM Series Biological Clean Bench
Biological clean bench is necessary for cell tissue culture in the fields of medicine, biological engineering and scientific lab.











Reviews
There are no reviews yet.